Courtenay Springs Village

Courtenay Springs Village
1200 S Courtenay Pkwy
Merritt Island, FL 32952
(321)452-1233

Click to Show Larger Map
Map of Area Around Courtenay Springs Village
Get Directions to Courtenay Springs Village 1200 S Courtenay Pkwy, Merritt Island, FL 32952
Directions From:

Driving To:
Simply enter your starting location into the box labeled “Directions From:” box above.
Property & Structure Photos from 1200 S Courtenay Pkwy
Click to Show Contents
No (0) Emergency Closure Orders Since October 2008
Click to Hide Contents
1 Lodging Establishment Inspection Since July 1, 2014
Inspection For: COURTENAY SPRINGS VILLAGE
License Number: 1503169
License ID: 2134260
Inspection Visit ID: 5279044
Inspection Date: Monday, October 27, 2014
Inspection Number: 1355542
Visit Number: 1
Inspection Class: Lodging
Inspection Type: Routine - Lodging
Inspection Disposition: Inspection Completed - No Further Action - Sanitary and safety conditions did not warrant a follow-up visit to ensure correction. Establishment will be inspected again at the next routine interval.
Total Number of Violations: 2
Number of High Priority Violations: 1
Number of Intermediate Violations: 0
Number of Basic Violations: 1
Details
ViolationObservations of Inspector [as written on inspection]
13-12-4 Basic.Stucco on entire exterior is in the process of being removed and replaced.
12-10-4 High Priority.Certificate of Balcony Inspection stamped by the Division's district office not available. Faxed to D4 office. Called D4 office and found out there is a stamped copy on file. **Corrected On-Site**

Click to Hide Contents
1 Lodging Establishment Inspection for July 1, 2013 - June 30, 2014
Inspection For: COURTENAY SPRINGS VILLAGE
License Number: 1503169
License ID: 2134260
Inspection Visit ID: 5002177
Inspection Date: Friday, October 04, 2013
Inspection Number: 1339603
Visit Number: 1
Inspection Class: Lodging
Inspection Type: Routine - Lodging
Inspection Disposition: Inspection Completed - No Further Action - Sanitary and safety conditions did not warrant a follow-up visit to ensure correction. Establishment will be inspected again at the next routine interval.
Total Number of Violations: 0
Number of High Priority Violations: 0
Number of Intermediate Violations: 0
Number of Basic Violations: 0

Click to Hide Contents
1 Lodging Establishment Inspection for July 1, 2012 - June 30, 2013
Inspection For: COURTENAY SPRINGS VILLAGE
License Number: 1503169
License ID: 2134260
Inspection Visit ID: 4642362
Inspection Date: Monday, February 25, 2013
Inspection Number: 1313690
Visit Number: 1
Inspection Class: Lodging
Inspection Type: Routine - Lodging
Inspection Disposition: Inspection Completed - No Further Action - Sanitary and safety conditions did not warrant a follow-up visit to ensure correction. Establishment will be inspected again at the next routine interval.
Total Number of Violations: 0
Number of High Priority Violations: 0
Number of Intermediate Violations: 0
Number of Basic Violations: 0

Click to Hide Contents
2 Lodging Establishment Inspections for July 1, 2011 - June 30, 2012
Inspection For: COURTENAY SPRINGS VILLAGE
License Number: 1503169
License ID: 2134260
Inspection Visit ID: 4527257
Inspection Date: Thursday, February 23, 2012
Inspection Number: 1292394
Visit Number: 2
Inspection Class: Lodging
Inspection Type: Routine - Lodging
Inspection Disposition: Call Back - Complied - Return visit from a previous warning found violations to be corrected.
Total Number of Violations: 0
Number of Critical/Risk Violations: 0
Number of Noncritical Violations: 0

Inspection For: COURTENAY SPRINGS VILLAGE
License Number: 1503169
License ID: 2134260
Inspection Visit ID: 4299530
Inspection Date: Thursday, December 22, 2011
Inspection Number: 1292394
Visit Number: 1
Inspection Class: Lodging
Inspection Type: Routine - Lodging
Inspection Disposition: Warning Issued - Sanitary and/or safety conditions require the inspector to return in the near future to ensure corrective action has been taken for violations found.
Total Number of Violations: 1
Number of Critical/Risk Violations: 1
Number of Noncritical Violations: 0
Details
ViolationObservations of Inspector [as written on inspection]
12-09 Critical. Observed an expired balcony certificate on 3/5/07. Repeat Violation. This violation must be corrected by : 02/23/2012.

Click to Hide Contents
1 Lodging Establishment Inspection for July 1, 2010 - June 30, 2011
Inspection For: COURTENAY SPRINGS VILLAGE
License Number: 1503169
License ID: 2134260
Inspection Visit ID: 4018982
Inspection Date: Wednesday, October 20, 2010
Inspection Number: 1279289
Visit Number: 1
Inspection Class: Lodging
Inspection Type: Routine - Lodging
Inspection Disposition: Inspection Completed - No Further Action - Sanitary and safety conditions did not warrant a follow-up visit to ensure correction. Establishment will be inspected again at the next routine interval.
Total Number of Violations: 1
Number of Critical/Risk Violations: 1
Number of Noncritical Violations: 0
Details
ViolationObservations of Inspector [as written on inspection]
12-09 Critical. Observed an expired balcony certificate.

Click to Hide Contents
1 Lodging Establishment Inspection for July 1, 2009 - June 30, 2010
Inspection For: COURTENAY SPRINGS VILLAGE
License Number: 1503169
License ID: 2134260
Inspection Visit ID: 3682376
Inspection Date: Thursday, May 06, 2010
Inspection Number: 1256873
Visit Number: 1
Inspection Class: Lodging
Inspection Type: Routine - Lodging
Inspection Disposition: Inspection Completed - No Further Action - Sanitary and safety conditions did not warrant a follow-up visit to ensure correction. Establishment will be inspected again at the next routine interval.
Total Number of Violations: 1
Number of Critical/Risk Violations: 1
Number of Noncritical Violations: 0
Details
ViolationObservations of Inspector [as written on inspection]
08-04 Critical. No carbon monoxide sensor device located in a gas boiler room in a building which also contains sleeping rooms. CO detector must be connected and intergrsted into existing fire alarm system. Boiler Information: Boiler Jurisdiction Number: FL094191, Boiler Expiration Date: 06/11/2010

Click to Hide Contents
3 Lodging Establishment Inspections for July 1, 2008 - June 30, 2009
Inspection For: COURTENAY SPRINGS VILLAGE
License Number: 1503169
License ID: 2134260
Inspection Visit ID: 3588168
Inspection Date: Thursday, June 18, 2009
Inspection Number: 1243160
Visit Number: 1
Inspection Class: Lodging
Inspection Type: Complaint Full
Inspection Disposition: Inspection Completed - No Further Action - Sanitary and safety conditions did not warrant a follow-up visit to ensure correction. Establishment will be inspected again at the next routine interval.
Total Number of Violations: 2
Number of Critical/Risk Violations: 2
Number of Noncritical Violations: 0
Details
ViolationObservations of Inspector [as written on inspection]
08-03-1 Critical. Observed a boiler certificate is not posted in the boiler room on east end of building. For reporting purposes only.
08-04 Critical. Observed carbon monoxide sensor device located in a gas boiler room in a building which also contains sleeping rooms is not integrated with the building's fire detection system. Repeat Violation. Bids obtained to do work, waiting on approval from corporate office. Boiler Information: Boiler Jurisdiction Number: FL 094192, Boiler Expiration Date: 11/26/09 Each apt has indivdual hot water heaters. Boiler is used during winter to heat water for heat system. Not operated during summer.

Inspection For: COURTENAY SPRINGS VILLAGE
License Number: 1503169
License ID: 2134260
Inspection Visit ID: 3493726
Inspection Date: Friday, January 09, 2009
Inspection Number: 1240644
Visit Number: 1
Inspection Class: Lodging
Inspection Type: Complaint Full
Inspection Disposition: Inspection Completed - No Further Action - Sanitary and safety conditions did not warrant a follow-up visit to ensure correction. Establishment will be inspected again at the next routine interval.
Total Number of Violations: 1
Number of Critical/Risk Violations: 1
Number of Noncritical Violations: 0
Details
ViolationObservations of Inspector [as written on inspection]
08-04 Critical. No carbon monoxide sensor device located in a gas boiler room in a building which also contains sleeping rooms. Detector must be tied into existing fire alarm system. Repeat Violation. Boiler Information: Boiler Jurisdiction Number: FL094192, Boiler Expiration Date: 11/26/09

Inspection For: COURTENAY SPRINGS VILLAGE
License Number: 1503169
License ID: 2134260
Inspection Visit ID: 3227985
Inspection Date: Friday, October 31, 2008
Inspection Number: 1216706
Visit Number: 1
Inspection Class: Lodging
Inspection Type: Routine - Lodging
Inspection Disposition: Inspection Completed - No Further Action - Sanitary and safety conditions did not warrant a follow-up visit to ensure correction. Establishment will be inspected again at the next routine interval.
Total Number of Violations: 3
Number of Critical/Risk Violations: 3
Number of Noncritical Violations: 0
Details
ViolationObservations of Inspector [as written on inspection]
04-13-2 Critical. Observed no inspection report available for the fire alarm system. For reporting purposes only. Enigeer stated bad stobe light has been called into service company.
08-04 Critical. No carbon monoxide sensor device located in a gas boiler room in a building which also contains sleeping rooms. Boiler Information: Boiler Jurisdiction Number: FL094192, Boiler Expiration Date: 11/26/09
08-04 Critical. Carbon monoxide sensor device required and located in a gas boiler room in a building which also contains sleeping rooms is not integrated with the building's fire detection system. Boiler Information: Boiler Jurisdiction Number: FL094192, Boiler Expiration Date: 11/26/09

Click to Hide Contents
1 Lodging Establishment Inspection for July 1, 2007 - June 30, 2008
Inspection For: COURTENAY SPRINGS VILLAGE
License Number: 1503169
License ID: 2134260
Inspection Visit ID: 2891252
Inspection Date: Monday, November 26, 2007
Inspection Number: 1186999
Visit Number: 1
Inspection Class: Lodging
Inspection Type: Routine - Lodging
Inspection Disposition: Inspection Completed - No Further Action - Sanitary and safety conditions did not warrant a follow-up visit to ensure correction. Establishment will be inspected again at the next routine interval.
Total Number of Violations: 4
Number of Critical/Risk Violations: 4
Number of Noncritical Violations: 0
Details
ViolationObservations of Inspector [as written on inspection]
06-20 Critical. Observed an emergency light that is not functioning when tested by apt unit 115.
08-03 Critical. Observed no boiler certificate available for new boiler for heat at 990,500 btu's ,installed in 1/2005. Boiler Information: No Boiler Certificate Provided for new gas boiler for heat at 990,500 btu's. 30 gallons electric hot water heaters in apatments.
08-04 Critical. No carbon monoxide sensor device located in a gas boiler room in a building which also contains sleeping rooms. Boiler Information: No Boiler Certificate Provided for new gas boiler for heat at 990,500 btu's. 30 gallons electric hot water heaters in apatments.
12-10 Critical. Observed no stamped Certificate of Balcony Inspection available.

Click to Hide Contents
3 Lodging Establishment Inspections for July 1, 2006 - June 30, 2007
Inspection For: COURTENAY SPRINGS VILLAGE
License Number: 1503169
Inspection Date: Monday, April 30, 2007
Inspection Number: 1174206
Visit Number: 3
Inspection Class: Lodging
Inspection Type: Routine - Lodging
Inspection Disposition: Call Back - Complied - Return visit from a previous warning found violations to be corrected.
Total Number of Violations: 0
Number of Critical/Risk Violations: 0
Number of Noncritical Violations: 0

Inspection For: COURTENAY SPRINGS VILLAGE
License Number: 1503169
Inspection Date: Wednesday, March 28, 2007
Inspection Number: 1174206
Visit Number: 2
Inspection Class: Lodging
Inspection Type: Routine - Lodging
Inspection Disposition: Call Back - Extension given, pending
Total Number of Violations: 1
Number of Critical/Risk Violations: 1
Number of Noncritical Violations: 0
Details
1 critical violation of code 12 which pertains to:
  • “Balcony, railing safety; certification”

Inspection For: COURTENAY SPRINGS VILLAGE
License Number: 1503169
Inspection Date: Monday, February 26, 2007
Inspection Number: 1174206
Visit Number: 1
Inspection Class: Lodging
Inspection Type: Routine - Lodging
Inspection Disposition: Warning Issued - Sanitary and/or safety conditions require the inspector to return in the near future to ensure corrective action has been taken for violations found.
Total Number of Violations: 1
Number of Critical/Risk Violations: 1
Number of Noncritical Violations: 0
Details
1 critical violation of code 12 which pertains to:
  • “Balcony, railing safety; certification”

NoticeEach inspection report is a “snapshot” of conditions present at the time of the inspection. On any given day Courtenay Springs Village in Merritt Island Florida may have fewer or more violations than noted in their most recent inspection. An inspection conducted on any given day may not be representative of the overall, long-term conditions at Merritt Island's Courtenay Springs Village.

A summary of violations found during inspections are listed in the Lodging Establishment Inspection boxes above. Cited are violations of Florida's sanitation and safety laws.

Effective January 1, 2013, the Florida Division of Hotels and Restaurants adopted a new three-tiered violation classification system that replaces the "critical" or "non-critical" classification in use up until then. The new system uses the terms "High Priority," "Intermediate" and "Basic" which better define violation information for consumers, making it easier to understand.

In general, High Priority violations are those which could pose a direct or significant threat to the public health, safety, or welfare. Although the Department of Business and Professional Regulation (DBPR) uses the term "High Priority", varying degrees of severity and potential risk to the public require inspectors to assess each situation in determining the appropriate action. In addition, while Courtenay Springs Village may have multiple violations, the inspectors' training and judgment formulate the overall result of the inspection to ensure public health and safety.

Intermediate violations are those which relate to specific actions, equipment or procedures that contribute to the occurrence of a high priority violation if left unaddressed. Basic violations are those which are considered best practices to implement.

Formally, Critical violations were those that involve life safety, sanitation and business practices. Noncritical violations included building disrepair, housekeeping problems or improper processing of room rate notices.

While most establishments correct all violations in a timely manner (often during the inspection), the division's procedures are designed to compel compliance with all violations through follow-up visits, administration action or closure when necessary.

Violations listed refer to the revelant section of Florida regulation that has been observed to be deficient during the inspection. Each establishment must comply with the language of the inspection statement. For purposes of enforcement and compliance, the DBPR recognizes the status as printed on the inspection form, although the severity of the violation observed may warrant additional action regardless of its "High Priority/Intermediate/Basic" or "critical/noncritical" designation.